These meters have the features needed to find most electrical, electro-mechanical and heating and ventilation problems. They are simple to use and have significant features like True-RMS, more measurement functions, conformance to the latest safety standards, and a much larger display that’s easier to view. They confirm to EN61010-1 CAT IV 600V, CAT III 1000V. 1000V input protection on all ranges 10A/1000V & 0.5A/1000V fuses protection on current ranges. The Dust and Waterproof IP67 makes it a tough instrument to be used in the most abusive environments.
| Function | Range | Resolution | Accuracy |
| DC Voltage | 600mV | 0.1mV | ± (0.09% reading + 2 digits) |
| 6V | 0.001V | ||
| 60V | 0.01V | ||
| 600V | 0.1V | ||
| 1000V | 1V | ± (0.15% reading + 2 digits) |
| Function | Range | Resolution | Accuracy | |
| AC Voltage | 50 to 60Hz | 40Hz to 1KHz | ||
| 6V | 0.001V | ± (1.0% reading + 3 dgts) | ± (2.0% reading + 3 dgts) | |
| 1000V | 1V | ± (1.2% reading + 3 dgts) | ± (2.5% reading + 3 dgts) | |
| All AC voltage ranges are specified from 5% of range to 100% of range | ||||
| Function | Range | Resolution | Accuracy |
| DC Current | 600mA | 0.1mA | ± (1.0% reading + 3 digits) |
| 6000mA | 1mA | ||
| 60mA | 0.01 mA | ||
| 600mA | 0.1mA | ||
| 6A | 0.001A | ± (1.5% reading + 3 digits) | |
| 10A | 0.01 A | ||
| (20A: 30 sec max with reduced accuracy) | |||
| Function | Range | Resolution | Accuracy |
| AC Current | 40Hz to 1kHz | ||
| 600mA | 0.1mA | ± (1.5% reading + 3 digits) | |
| 6000mA | 1mA | ||
| 60mA | 0.01 mA | ||
| 600mA | 0.1mA | ||
| 6A | 0.001A | ± (2.0% reading + 3 digits) | |
| 10A | 0.01 A | ||
| (20A: 30 sec max with reduced accuracy) | |||
| All AC Current ranges are specified from 5% of range to 100% of range | |||
| Function | Range | Resolution | Accuracy |
| Resistance | 600Ω | 0.1Ω | ± (0.3% reading + 4 digits) |
| 6kΩ | 0.001kΩ | ||
| 60kΩ | 0.01kΩ | ||
| 600kΩ | 0.1kΩ | ||
| 6MΩ | 0.001MΩ | ||
| 60MΩ | 0.01MΩ | ± (0.5% reading + 20 digits) |
| Function | Range | Resolution | Accuracy |
| Capacitance | 60nF | 0.01 nF | ± (3.5% reading + 4 digits) |
| 600nF | 0.1 nF | ||
| 6µF | 0.001µF | ||
| 60µF | 0.01µF | ||
| 600µF | 0.1µF | ||
| 1000µF | 1µF | ± (5% reading + 5 digits) |
| Function | Range | Resolution | Accuracy |
| Frequency (electronic) | 9.999Hz | 0.001 Hz | ± (0.1% reading + 1 digits) |
| 99.99Hz | 0.01 Hz | ||
| 999.9Hz | 0.1 Hz | ||
| 9.999kHz | 0.001 kHz | ||
| 99.99kHz | 0.01 kHz | ||
| 999.9kHz | 0.1 kHz | ||
| 9.999MHz | 0.001 MHz | ||
| 40MHz | 0.01 MHz | ||
| Sensitivity: 0.8V RMS min. @ 20% to 80% duty cycle and <100kHz; 5V RMS min @ 20% to 80% duty cycle and > 100 kHz. | |||
| Function | Range | Resolution | Accuracy |
| Frequency (electrical) | 10.00-400Hz | 0.01Hz | ± (0.5% reading) |
| Sensitivity: 15V RMS | |||
| Function | Range | Resolution | Accuracy |
| Duty Cycle | 0.1 to 99.9% | 0.10% | ± (1.2% reading + 2 digits) |
| Pulse width: 100µs - 100ms, Frequency: 5Hz to 150 kHz | |||
| Function | Range | Resolution | Accuracy |
| Temp (type-K) | -50 to 1382°F | 1°F | ± (3.0% reading + 5°C /9°F digits) |
| -45 to 750°C | 1°C | (probe accuracy not included) |